How to add slicing loss to a multi-cut module
SunSolve Power captures the current and resistance benefits of multi-cut cells automatically, but it does not infer the slicing loss from the cut. This guide simulates a multi-cut module without slicing loss, then adds the loss by increasing the baseline J02.
To add slicing loss to a multi-cut module
Section link: To add slicing loss to a multi-cut moduleBuild the multi-cut module: Set the cut cell dimensions on the Inputs → Cell geometry and the cell count and any group gaps on the Inputs → Module cell layout, matching a three-cut or four-cut design.
Solve without slicing loss: Run the simulation. The result includes the reduced per-cell current and resistive loss of the cut cells but no slicing penalty. Note the maximum power and fill factor as the baseline.
Enable modifiers: On the Inputs → Options tab enable the electrical solver and electrical modifiers.
Add a J02 modifier: On the Inputs → Modifiers tab set the scope to Single module, add a modifier with the target Every cell, and add the J02 parameter. Enter a multiplier greater than 1, sized from measured before-and-after cell data or a known slicing-loss figure for the process.
Re-solve and compare: The electrical solver reruns without a new ray trace. Compare the maximum power and fill factor with the baseline to read the slicing loss.