Many users cross-reference SunSolve results against PVsyst. The tables below map each
SunSolve yield output to its nearest PVsyst equivalent, with notes where the definitions
or implementations differ. Where PVsyst has no direct equivalent this is indicated with an
em dash (—).
| Parameter | Symbol | PVsyst equivalent | Notes |
|---|
| Reference plane of array irradiance | Gi,ref | — | |
| Front plane-of-array irradiation | HPOA,f | GlobShd | Effectively this is the GlobInc corrected for optical losses due to row-to-row shading, since SunSolve's view factor model includes that in the calculation. |
| Rear plane-of-array irradiation | HPOA,r | GlobBak | Although it is worth noting that SunSolve and PVsyst have differences in the implementation of the view-factor model. |
| Parameter | Symbol | PVsyst equivalent | Notes |
|---|
| Energy yield | Eout | System Production | |
| Specific yield | YS | Specific production | |
| Performance ratio | PR | Performance Ratio | |
| Bifacial performance ratio | PRbifi | Bifacial perf. ratio | |
| Average daily specific yield | Ys,daily | Normalised production | |
| Array losses (normalised) | Lc, norm | Array losses | |
| Normalised balance of system loss | LBOS,norm | System losses Ls | |
| Parameter | Symbol | PVsyst equivalent | Notes |
|---|
| DC power rating | P0 | Array nom. Power (STC) [kWp] / Nominal (STC) [kWp] / Pnom total [kWp] / System power [kWp] | |
| Module bifaciality | φ | — | PVsyst typically applies the bifaciality to increase the front-side irradiance instead. |
| Reference yield | Yr | Reference incident energy in coll. plane / Yr | |
| Bifacial reference yield | Yr,bifi | — | PVsyst does not have a direct equivalent metric. |
| Rear-side contribution to reference yield | Gbifi | — | PVsyst does not have a direct equivalent metric. |
| Array capture loss | Lc | — | PVsyst presents a normalised array capture loss referred to as 'Array Losses'. |
| Balance of system loss | LBOS | — | PVsyst presents a normalised BOS loss referred to as 'System Loss'. |